Product model | YH1600 Haze Meter |
Illumination mode | Transmittance: 0/D (parallel illumination, diffuse receiving) in accordance with standards: ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, GB/T 3978, ASTM E308, JIS K7105, JIS K7361, JIS K 7136 |
Characteristic | The instrument can easily realize ASTM D1003 uncompensated method, ISO 13468 compensation method, full transmittance, fog test. The instrument can accurately collect the transmittance curve of the transmitted sample, and can accurately output various chroma data of the transmitted sample. High hardware configuration, open measurement area, vertical, horizontal testing. It is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects. |
Integrating sphere size | Φ 154 mm |
Illumination source | 400 ~ 700 nm combined LED light source (wavelength scalable customized) |
Light splitting mode | Concave grating |
Inductor | 256 pixel dual array CMOS image sensor |
Measuring wavelength range | 400 ~ 700 nm (wavelength scalable customization) |
Wavelength interval | 10 nm |
Half bandwidth | 10 nm |
Determination range of transmittance | 0-100% |
Measuring aperture | Φ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture) |
Sample size | Thickness less than 170 mm |
Color space | CIE LAB, XYZ, Yxy, LCh, s-RGB, βxy |
Chromatic formula | ΔEab, ΔE94, ΔEcmc (2:1), ΔEcmc (1:1), ΔE00 |
Other chromaticity indicators | Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM) WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), Absorbance, Cobalt Platinum Index, Gardner Index |
Observer angle | 2 °/10 ° |
Observation light source | D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
Display | Spectrogram, sample chroma value, color difference/graph, color graph, color simulation, pass/fail result |
Measurement time | About 1.5s |
Resolution of fog | 0.01 unit |
Repeatability of nebulization | Φ20 mm aperture, less than 0.08 (after instrument preheating and correction, test the standard nebulizer with the nebulization of about 40 at an interval of 5s for 30 times of standard deviation) |
Inter-stage difference | Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5s) |
Dimensions | Length X Width X Height = 290X211X511 mm |
Weight | Approx. 7.6 kg |
Power supply mode | 24 V DC, supplied by 3A power adapter |
Illumination light source lifetime | > 3 million measurements in 5 years |
Display screen | TFT True Color 7 inch, Capacitive Touchscreen |
Interface | USB, Print Serial, Bluetooth |
Stored Data | 5,000 samples, 20,000 samples |
Language | Simplified Chinese, Traditional Chinese, English |
Operating Temperature Range | 0 to 40 ° C (32 to 104 ° F) |
Storage Temperature Range | - 20 – 50 ° C (-4 – 122 ° F) |
Standard Annex | Power adapter, instruction for use, quality management software (download), data cable, 0% calibration box, measuring caliber |
Optional Accessories | Microprinter, Test Fixture, Standard Fog Disk, Footswitch |
Notes: | Subject to change without notice |